Train Lighting / Air Conditioning - Low Maintenance Battery

Brand Name : STAR PLUS
As per RDSO Specification: RDSO / PE / SPEC / AC / 0058-2005 with latest amendment

Technical Data :
Type C10 rate (Ah) (V) Dimensions (in mm) Type of Container Weight ( in Kg.) Filling Sp. Gr.
at 27°C
Final Sp. Gr.
at 27°C
Volume per Cell(in Litres)
Length Width Height (OA) Dry Filled
6T 120 PP 120 6 450 ± 3 181 ± 3 380 ± 3 PPCP 21 ± 5% 37.0 ± 5% 1.190±0.005 1.215±0.005 5.1
2T 800 HR 800 2 394 ± 3 191 ± 2 497 ± 3 Hard Rubber 50 ± 5% 70.0 ± 5% 1.230±0.005 1.245±0.005 16.8
Summary of Different Charging Modes :
Type Initial Charge Limiting Current (Amps.) Normal Charge Limiting Current (Amps.) Equalizing Amps. & Hrs. Boost Amps. & Hrs. Trickle Amps. Max. Electrolyte Temp. Allow
Short Period Continuously
6T 120 PP 8.8 for 75 Hrs. 12.0 for 15 Hrs. Normal rate continued by 1/30th C10 rate.
1.5 times of the normal rate of charging
120 mA 54°C 48°C
2T 800 HR 59.0 for 75 Hrs. 80.0 for 15 Hrs. 800 mA 54°C 48°C